Intel Rapid Storage Technology RAID Driver 12.8.0.1016 for Windows 7/8/8.1 Windows Server 2008/2012 x86/x64

User Drivers » RAID & HD Controller » Intel »
Date Added: August 11, 2013 / Publisher:Intel / File Size: 0.35 MB
OS: Windows 7, Windows 7 x64, Windows 8, Windows 8 x64, Windows Server 2008, Windows Server 2008 x64, Windows Server 2008 R2 x64, Windows Server 2012, Windows Server 2012 x64, Windows 8.1, Windows 8.1 x64

Download

Release Date: August 11, 2013.

Release Date: August 8, 2013.

Resolved Issues in 12.8.0.1016 Production Version release:

  1. RST driver disables LPM (HIPM/DIPM) when system enters S4.
  2. Bad status bytes when sending ATA Smart Command Transport (SCT) commands.
  3. BSOD 0x7A occurred when run WinPMT Hibernation Focus.
  4. Zpodd: Start Stop Unit command fails when drive is asleep.
  5. C5 BSOD when shut down the system from start menu.

Known Issues in 12.8.0.1016 Production Version release:

  1. BLA cannot detect storage device with RST Driver version -CSMI.
  2. Option to keep data present on certain fully partitioned disks in GPT format scheme when should not be.
  3. WHQL: DF - Sleep With IO During (Certification) failure in RST 12.8 (NOT BLOCKING).
  4. UI: Format issue with Server 2012 string in System Requirements help page.
  5. SSHD accelerated in max mode with iSCT loaded onto system causes system to hang when trying to restart or go into S4.
  6. UI sporadically crashes during volume delete operations.
  7. UI: Help Icon present on Status page when it should not be present with only 1 SSHD (OS) attached to the system.
  8. BSOD "Driver Power State Failure" when accelerated HDDpw volume is locked upon wake up from S4.
  9. Invoking "Create Additional Volume" page yields an unknown error.
  10. System hung on a Black screen or reboot when resuming from S1-S3 (S3 after S1).
  11. UI Help - Getting Started Page - Incorrect Grammar.
  12. UI: Day field in Verify and Repair Scheduler does not set the Next Scheduled Run correctly.
  13. UI: Disk Events Help Page has incorrect images.
  14. ATAPI Pass-through path only handles Packet Identify Device.
  15. Ability to change write-cache buffer flushing policy is broken after changing volume name.
  16. After configuring SRT and conducting Dirty Shutdowns error: Unable to find System Disk.
  17. BSOD 0xF4: Accelerate/Change NVM mode to Enhanced/ Changing RST Caching mode to Enhanced on disk.
  18. Bad Block Tests Fail With Volumes Going Degraded During the Verify and Repair Operation.
  19. CLI Command --accelerate --stats always returns 100% cache full.
  20. Constant events being sent after RRT creation.
  21. Deleting a non-OS matrix volume while it is migrating marks added disks as unknown.
  22. Failing R0 volume amidst an i/o onto it while system is in S3 causes system to hang/crash upon resume.
  23. Dynamic storage Accelerator: Setting system performance mode to "HighPerformance" does not cause gear to change to gear 3.
  24. Missing Mark Disk as Online event in Driver.
  25. RRT PM S4 command issued but does not recover.
  26. RRT failed master disk goes offline when setting disks to normal.
  27. RST Driver - Test hangs while running Inquiry command on ODD.
  28. RSTCLI allows RAID volume comprised of SSDs to be accelerated.
  29. SRT Driver Fails "No Spin" TIME IOCTL request on FIRST S0 following S3 with PUIS enabled.
  30. SRT volumes do not report disk RPM = 1, breaks Win8 Connected Standby.
  31. SRT: Driver fails to enumerate an accelerated disk or volume during an F6 install if a system disk is already attached to the system.
  32. UI Accessibility: Refresh issues when changing theme and arrow keys not functional in Help window.
  33. UI Unknown error enabling Volume write-back cache.
  34. UI allows locked spare disk to be reset to available after S4 resumption; exercising the option induces errors.
  35. UI erroneously exposes option to increase size of a >2TB volume if is created via the OROM.
  36. UI hangs and throws unknown error if we attempt to update data on an OnREQ RRT vol of SSDs.
  37. UI reports Unknown status and incorrect sync mode after hot-removing the recovery disk of an IRRTm while the sync is initializing.
  38. UI shows "Mark as normal" link while a volume is rebuilding.
  39. UI will sporadically fail to refresh itself to render Enable acceleration and Refresh button clickable.
  40. UI: "WARNING:" text missing on "Disassociate Cache and Accelerated Device" Popup Window.
  41. WHQL: 0xCE BSOD during DP CPU Hot Add simulation on Server 2008 R2.
  42. WHQL: RST not compliant with Device.DevFund.Memory.DriverFootprint requirements for x86.
  43. ZPODD power off timer does not reset upon receipt of CSMI I/O.

Recent Drivers

Intel RAID Controller RS3FC044/RS3GC008/RS3UC080 Firmware Update Package ph1_2013.08.16
Intel Rapid Storage Technology RAID Driver 12.8.0.1016 for Windows 7/8/8.1 Windows Server 2008/2012 x86/x64
Intel Solid-State Drive (SSD) Data Center Tool 1.1 for Windows/Linux
Intel Solid-State Drive Toolbox 3.1.6 for Windows XP/Vista/7/8
Intel SATA Solid-State Drive Firmware Update Tool 2.0.4